Shelter Equipment
Shelter Leveling & Stabilization System
The shelter leveling and stabilization system is designed to enable fast, safe, and precise positioning of shelters across various terrain conditions. Its automatic leveling function compensates for ground inclination and brings the platform to a stable and horizontal position. Operated with a single command, the system reduces deployment time, minimizes personnel requirements, and improves efficiency during field setup. Its robust design provides reliable stabilization and continuous platform balance under demanding operational conditions.
Technical Specifications
| System Function | Fully automatic leveling and stabilization |
| Control Method | Automatic leveling (manual control available) |
| Actuation Method | Electromechanical |
| Leveling Range | 0 – 1800 mm |
| Leveling Time | < 4 minutes |
| Load Capacity | < 30 tons |
| Power Consumption | < 10 kW |
| Standards | MIL-STD-810 H, MIL-STD-461 G |
The full specifications are in the technical document below.
Technical Documents
Overview
Shelter Leveling and Stabilization System is a mechanical jack set that brings mobile shelters to a horizontal position after deployment and keeps them stable throughout their site service life. On sloped, uneven or soft ground, having the shelter floor horizontal is directly decisive for personnel movement safety, door and window sealing, interior equipment alignment and proper operation of sensitive electronics. Ozben Defence supplies this system in configurations compatible with ACE, NATO, ISO and special-type shelter platforms.
Key Features
- Mechanical jack sets
- Typically placed at the four corners of the shelter; each jack is sized to independently carry the load at its corner.
- Manual or mechanical control
- Height adjustment is performed via a handle or a reduction mechanism depending on configuration.
- Wide base plate
- Load-spreading base that prevents the jack foot from sinking into soft ground.
- Corrosion-resistant surface treatment
- Long service life in marine, desert and tropical climates.
- Shelter interface
- Compatible with existing shelter corner castings or dedicated mounting feet.
Operating Principle
After the shelter is set down on site, each corner jack is operated individually to bring the platform to a horizontal position. Using a spirit level or a level indicator, each jack is adjusted until its corner rests on the horizontal plane. All feet are then locked in position. The platform can be detached from the transport vehicle or, if required, remain on the vehicle; the jack set takes on part or all of the load throughout long-duration deployment, relieving the vehicle suspension.
International Standards
- NATO STANAG 2413
- Mobile shelter interfaces and site installation.
- MIL-STD-810H
- Environmental endurance (vibration, shock, temperature, humidity).
Applications
- Short- and long-duration deployments on sloped or uneven sites.
- Installation on soft ground (sand, mud, snow).
- Long-duration fixed mission posts (command post, radar operator cabin).
- Units such as field hospitals, surgical suites, laboratories where interior alignment is critical.
- Precision antenna alignment in electronic warfare and signals intelligence cabins.
System Selection
The right jack selection depends on the fully loaded shelter weight, site ground properties, deployment duration and the shelter interface. The Özben engineering team plans jack selection, interface design and site installation training together for both new shelter projects with integrated supply and retrofit applications on existing shelters. For a detailed RFQ, please contact our engineering team.